12 research outputs found

    Acoustical structured illumination for super-resolution ultrasound imaging.

    Get PDF
    Structured illumination microscopy is an optical method to increase the spatial resolution of wide-field fluorescence imaging beyond the diffraction limit by applying a spatially structured illumination light. Here, we extend this concept to facilitate super-resolution ultrasound imaging by manipulating the transmitted sound field to encode the high spatial frequencies into the observed image through aliasing. Post processing is applied to precisely shift the spectral components to their proper positions in k-space and effectively double the spatial resolution of the reconstructed image compared to one-way focusing. The method has broad application, including the detection of small lesions for early cancer diagnosis, improving the detection of the borders of organs and tumors, and enhancing visualization of vascular features. The method can be implemented with conventional ultrasound systems, without the need for additional components. The resulting image enhancement is demonstrated with both test objects and ex vivo rat metacarpals and phalanges

    Imaging beyond ultrasonically-impenetrable objects

    Get PDF
    Abstract Ultrasound images are severely degraded by the presence of obstacles such as bones and air gaps along the beam path. This paper describes a method for imaging structures that are distal to obstacles that are otherwise impenetrable to ultrasound. The method uses an optically-inspired holographic algorithm to beam-shape the emitted ultrasound field in order to bypass the obstacle and place the beam focus beyond the obstruction. The resulting performance depends on the transducer aperture, the size and position of the obstacle, and the position of the target. Improvement compared to standard ultrasound imaging is significant for obstacles for which the width is larger than one fourth of the transducer aperture and the depth is within a few centimeters of the transducer. For such cases, the improvement in focal intensity at the location of the target reaches 30-fold, and the improvement in peak-to-side-lobe ratio reaches 3-fold. The method can be implemented in conventional ultrasound systems, and the entire process can be performed in real time. This method has applications in the fields of cancer detection, abdominal imaging, imaging of vertebral structure and ultrasound tomography. Here, its effectiveness is demonstrated using wire targets, tissue mimicking phantoms and an ex vivo biological sample

    Visualization 1: Superresolved nanoscopy using Brownian motion of fluorescently labeled gold nanoparticles

    No full text
    Construction of the super resolution image Originally published in Applied Optics on 10 February 2017 (ao-56-5-1365

    Enhanced microbubble contrast agent oscillation following 250 kHz insonation

    No full text
    Abstract Microbubble contrast agents are widely used in ultrasound imaging and therapy, typically with transmission center frequencies in the MHz range. Currently, an ultrasound center frequency near 250 kHz is proposed for clinical trials in which ultrasound combined with microbubble contrast agents is applied to open the blood brain barrier, since at this low frequency focusing through the human skull to a predetermined location can be performed with reduced distortion and attenuation compared to higher frequencies. However, the microbubble vibrational response has not yet been carefully evaluated at this low frequency (an order of magnitude below the resonance frequency of these contrast agents). In the past, it was assumed that encapsulated microbubble expansion is maximized near the resonance frequency and monotonically decreases with decreasing frequency. Our results indicated that microbubble expansion was enhanced for 250 kHz transmission as compared with the 1 MHz center frequency. Following 250 kHz insonation, microbubble expansion increased nonlinearly with increasing ultrasonic pressure, and was accurately predicted by either the modified Rayleigh–Plesset equation for a clean bubble or the Marmottant model of a lipid-shelled microbubble. The expansion ratio reached 30-fold with 250 kHz at a peak negative pressure of 400 kPa, as compared to a measured expansion ratio of 1.6 fold for 1 MHz transmission at a similar peak negative pressure. Further, the range of peak negative pressure yielding stable cavitation in vitro was narrow (~100 kPa) for the 250 kHz transmission frequency. Blood brain barrier opening using in vivo transcranial ultrasound in mice followed the same trend as the in vitro experiments, and the pressure range for safe and effective treatment was 75–150 kPa. For pressures above 150 kPa, inertial cavitation and hemorrhage occurred. Therefore, we conclude that (1) at this low frequency, and for the large oscillations, lipid-shelled microbubbles can be approximately modeled as clean gas microbubbles and (2) the development of safe and successful protocols for therapeutic delivery to the brain utilizing 250 kHz or a similar center frequency requires consideration of the narrow pressure window between stable and inertial cavitation